Definitions of Managed Objects for Data Link Switching using SMIv2
Voir toute la rfc dans une seule page
Page : 65 / 90
Télécharger le PDF
Auteur(s) :
S. Nix,
Editor D. Chen,
P. Gayek
Classé sous :
Mib,
Management,
Information,
Base,
Dlsw-mib,
Dlsw
RFC 2024 DLSw MIB using SMIv2 October 1996
The value zero should be returned if this circuit is not
running the DLSw pacing protocol."
::= { dlswCircuitEntry 20 }
dlswCircuitFCRecvGrantedUnits OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of paced SSP messages that this DLSw has
authorized the partner DLSw to send on this circuit before
the partner DLSw must stop and wait for an additional flow
control indication from this DLSw.
The value zero should be returned if this circuit is not
running the DLSw pacing protocol."
::= { dlswCircuitEntry 21 }
dlswCircuitFCRecvCurrentWndw OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current window size that this DLSw is using in its role
as a data receiver. This is the number of additional paced
SSP messages that this DLSw would be authorizing its DLSw
partner to send, if this DLSw were to send a flow control
indication with the bits specifying `repeat window'.
The value zero should be returned if this circuit is not
running the DLSw pacing protocol."
::= { dlswCircuitEntry 22 }
dlswCircuitFCLargestRecvGranted OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The largest receive window size granted by this DLSw during
the current activation of this circuit. This is not the
largest number of messages granted at any time, but the
largest window size as represented by FCIND operator bits.
The value zero should be returned if this circuit is not
running the DLSw pacing protocol."
::= { dlswCircuitEntry 23 }
dlswCircuitFCLargestSendGranted OBJECT-TYPE
Chen, et. al. Standards Track [Page 65]